Description
The HPM Series Peristaltic Pump is easy-to-use for liquid transfer or dispensing applications. The aluminum alloy housing makes cleaning simple and the 4.3" LCD touch screen interface with a mechanical keypad provides an intuitive interface for users to configure operating modes such as speed-based, time-based, or volume-based pumping.
We are currently unable to support troubleshooting for applications requiring RS232/RS485 MODBUS communication at this time.
Flow rate vs tubing size was measured using water at room temperature. Many variables such as temperature, pressure, viscosity, resistance, etc will affect the final flow rate.
Tubing # | ID x WT (mm) | mL/RPM | Flow Rate (mL/min) | EasyPump Model | Intermittent Max. Pressure |
#13 | 0.8 x 1.6 | 0.053 | 0.053 - 32 | I, III, V, & VI | 0.27 MPa |
#14 | 1.6 x 1.6 | 0.27 | 0.027 - 162 | I, III, V, & VI | 0.27 MPa |
#19 | 2.4 x 1.6 | 0.55 | 0.055 - 330 | I, III, V, & VI | 0.27 MPa |
#16 | 3.2 x 1.6 | 0.93 | 0.093 -560 | I, III, V, & VI | 0.27 MPa |
#25 | 4.8 x 1.6 | 2.0 | 0.20 - 1180 | I, III, V, & VI | 0.24 MPa |
#17 | 6.4 x 1.6 | 3.3 | 0.33 - 2000 | I & III | 0.14 MPa |
#18 | 7.9 x 1.6 | 4.3 | 0.43 - 2580 | I & III | 0.10 MPa |
#15 | 4.8 x 2.4 | 1.8 | 0.18 - 1080 | II & IV | 0.27 MPa |
#24 | 6.4 x 2.4 | 2.7 | 0.27 -1640 | II & IV | 0.27 MPa |
#35 | 7.9 x 2.4 | 3.8 | 0.38 -2300 | II & IV | 0.24 MPa |
#36 | 9.6 x 2.4 | 5.2 | 0.52 - 3100 | II & IV | 0.24 MPa |